Maretron FFM100 Manual de usuario

Busca en linea o descarga Manual de usuario para De medición, control y control Maretron FFM100. Maretron FFM100 User`s manual Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 28
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 0
Revision 1.3 Page i
FFM100
Fuel Flow Monitor
User’s Manual
Revision 1.3
Copyright © 2013 Maretron, LLP All Rights Reserved
Maretron, LLP
9014 N. 23
rd
Ave #10
Phoenix, AZ 85021
http://www.maretron.com
Maretron Manual Part #: M003010
Vista de pagina 0
1 2 3 4 5 6 ... 27 28

Indice de contenidos

Pagina 1 - User’s Manual

Revision 1.3 Page i FFM100 Fuel Flow Monitor User’s Manual Revision 1.3 Copyright © 2013 Maretron, LLP All Rights

Pagina 2 - Revision History

FFM100 User’s Manual Page 6 Revision 1.3 into account will result in the fuel consumption being underestimated. In fact, without compen

Pagina 3 - Table of Contents

Revision 1.3 Page 7 Max. return flow rate = 5 gallons / 0.25 hours = 20 gallons per hour Now, add in the engine’s consumption fuel rate at

Pagina 4 - Table of Appendices

FFM100 User’s Manual Page 8 Revision 1.3 1.6.7 Choosing a Fluid Flow Sensor Mounting Location Choosing a proper mounting location for

Pagina 5 - 1 General

Revision 1.3 Page 9 2.3 Mounting the FFM100 Attach the FFM100 securely to the vessel using the included stainless steel mounting screws or

Pagina 6 - 1.6 Theory of Operation

FFM100 User’s Manual Page 10 Revision 1.3 Pin # Signal Name Connection 1 P0 Fluid flow sensor 0 power connection 2 G0 Fluid flow senso

Pagina 7 - Revision 1.3 Page 3

Revision 1.3 Page 11 that the collar on the cable connector is tightened firmly. Connect the other end of the cable (male) to the NMEA 2000

Pagina 8

FFM100 User’s Manual Page 12 Revision 1.3 c. Engine Label (Section 3.4.3) d. K-Factor (Section 3.4.4) e. Data Damping Period (Sectio

Pagina 9 - Revision 1.3 Page 5

Revision 1.3 Page 13 see negative flow rates from the Channel #0 sensor, you may change this parameter to “No”. When this parameter is set

Pagina 10 - FFM100 User’s Manual

FFM100 User’s Manual Page 14 Revision 1.3 rate of the fuel actually consumed by the engine, and is transmitted as a single parameter ov

Pagina 11 - Revision 1.3 Page 7

Revision 1.3 Page 15 3.4.8 Configuring Channel #0 Temperature Source Program this parameter to match the desired instance number of the te

Pagina 12 - 2 Installation

FFM100 User’s Manual Page ii Revision 1.3 Revision History Revision Description 1.0 Release for Review 1.1 Public Release 1.2 Correcte

Pagina 13 - 2.5 Connecting the FFM100

FFM100 User’s Manual Page 16 Revision 1.3 In a diesel engine, the diesel fuel is used to help cool the fuel injection system. Therefore

Pagina 14

Revision 1.3 Page 17 4 Maintenance Regular maintenance is not required; however, an occasional inspection will ensure continued proper ope

Pagina 15 - 3 Configuring the FFM100

FFM100 User’s Manual Page 18 Revision 1.3 5 Troubleshooting If you notice unexpected operation of the Maretron FFM100, follow

Pagina 16 - 3.1 Advanced Configuration

Revision 1.3 Page 19 6 Technical Specifications Specifications Parameter Value Comment Accuracy (Differential Mode) ±1.75% of reading Usin

Pagina 17

FFM100 User’s Manual Page 20 Revision 1.3 Environmental Parameter Value IEC 60945 Classification Exposed Degree of Protection IP64 Oper

Pagina 18 - 3.4 Configuring Channel #0

Revision 1.3 Page 21 8 Installation Template Please check the dimensions before using the following diagram as a template for drilling the

Pagina 19 - 3.5 Configuring Channel #1

FFM100 User’s Manual Page 22 Revision 1.3 9 Maretron (2 Year) Limited Warranty Maretron warrants the FFM100 to be free from defects i

Pagina 20

Revision 1.3 Appendix A – NMEA 2000® Interfacing Page A1 Appendix A – NMEA 2000® Interfacing FFM100 NMEA 2000® Periodic Data Transmitted PG

Pagina 21 - 4 Maintenance

FFM100 User’s Manual Page A2 Appendix A – NMEA 2000® Interfacing Revision 1.3 6: Fuel Rate – (16-bit signed integer) This field indica

Pagina 22 - 5 Troubleshooting

Revision 1.3 Page iii Table of Contents 1 General ...

Pagina 23 - 6 Technical Specifications

FFM100 User’s Manual Page iv Revision 1.3 3.5 Configuring Channel #1 ...

Pagina 24 - 7 Technical Support

Revision 1.3 Page 1 1 General 1.1 Introduction Congratulations on your purchase of the Maretron Fuel Flow Monitor (FFM100). Maretron has d

Pagina 25 - 8 Installation Template

FFM100 User’s Manual Page 2 Revision 1.3 1. Unpack the Box (Section 2.1) 2. Choose a Mounting Location (Section 2.2) 3. Mount the F

Pagina 26

Revision 1.3 Page 3 Figure 1 - M1RSP-2R-E8 and M2RSP-2R-E8 Accuracy and Pressure Loss Please refer to Figure 2 below for a chart detailin

Pagina 27 - Interfacing

FFM100 User’s Manual Page 4 Revision 1.3 Figure 2 - M4ARP-2-E8 Typical Accuracy and Pressure Loss 1.6.3 Diesel Fuel Flow Measurement

Pagina 28

Revision 1.3 Page 5 Figure 3 - Diesel Fuel Rate Measurement Fluid Flow Sensor Locations 1.6.4 Temperature Compensation The task of comp

Comentarios a estos manuales

Sin comentarios