Maretron ACM100 Manual de usuario

Busca en linea o descarga Manual de usuario para Monitores Maretron ACM100. Maretron ACM100 User Manual Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 24
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 0
Revision 1.2 Page i
®®
ACM100
Alternating Current Monitor
User’s Manual
Revision 1.2
Copyright © 2012 Maretron, LLP All Rights Reserved
Maretron, LLP
9014 N. 23
rd
Ave #10
Phoenix, AZ 85021-7850
http://www.maretron.com
Maretron Manual Part #: M001701
Vista de pagina 0
1 2 3 4 5 6 ... 23 24

Indice de contenidos

Pagina 1 - User’s Manual

Revision 1.2 Page i ®® ACM100 Alternating Current Monitor User’s Manual Revision 1.2 Copyright © 2012 Maretron

Pagina 2 - Revision History

ACM100 User’s Manual a. Connect the black wire to pin 7 (IA+) on the ACM100 b. Connect the white wire to pin 8 (IA-) on the ACM100 c. Disconnec

Pagina 3 - Table of Figures

Revision 1.2 Page 7 ®®will need to purchase an optional current sensor (Part # M000630) for monitoring this type of system. Step 1: De-ene

Pagina 4 - Table of Appendices

ACM100 User’s Manual 2.4.2.3 Three-Phase (Phase A, B, C) Connection Please refer to Figure 5 for connecting the ACM100 to a three phase system.

Pagina 5 - 1 Introduction

Revision 1.2 Page 9 ®®c. Disconnect the Phase B hot wire from the AC power source and place it through the hole in the Current Sensor such

Pagina 6 - 2 Installation

ACM100 User’s Manual Page 10 Revision 1.2 c. Connect the black wire from one end of the second Voltage Sense cable to pin 3 (VCLine) on t

Pagina 7 - 2.4 Connecting the ACM100

Revision 1.2 Page 11 ®®2.5.3 AC Circuit Type You must configure the ACM100 as to what type of AC circuit connection it is monitoring. The

Pagina 8

ACM100 User’s Manual Page 12 Revision 1.2 reconnecting the current transformer, you may change the value of this parameter from the defaul

Pagina 9 - Revision 1.2 Page 5

Revision 1.2 Page 13 ®®3.1 Line-Specific and Line-to-Neutral Measurements Parameter AC Source Type Available Data Bus Generator Utility

Pagina 10 - ACM100 User’s Manual

ACM100 User’s Manual Page 14 Revision 1.2 • Clean the unit with a soft cloth. Do not use chemical cleaners as they may remove paint or m

Pagina 11 - Revision 1.2 Page 7

Revision 1.2 Page 15 ®®6 Technical Specifications As Maretron is constantly improving its products, all specifications are subject to chan

Pagina 12

ACM100 User’s Manual Page ii Revision 1.2 Revision History Revision Description 1.0 Original document 1.1 Corrected AC sensor part numbe

Pagina 13 - Revision 1.2 Page 9

ACM100 User’s Manual Page 16 Revision 1.2 Electrical Parameter Value Comment Sensed Voltage 0-240 VAC 120,120/240,240,208Y,380Y confi

Pagina 14 - 2.5 Configuring the ACM100

®®8 Installation Template Please check the dimensions before using the following diagram as a template for drilling the mounting holes because t

Pagina 15 - 2.5.3 AC Circuit Type

ACM100 User’s Manual Page 18 Revision 1.2 9 Maretron (2 Year) Limited Warranty Maretron warrants the ACM100 to be free from defects in ma

Pagina 16 - 3 Output Parameters

Revision 1.2 Appendix A – NMEA 2000 Interfacing Page A1 ®®Appendix A – NMEA 2000® Interfacing ACM100 NMEA 2000® Periodic Data Transmitted

Pagina 17 - 4 Maintenance

ACM100 User’s Manual Page A2 Appendix A – NMEA 2000 Interfacing Revision 1.2 PGN 65005 – Utility Total AC Energy PGN 65018 – Generator Total

Pagina 18 - 5 Troubleshooting

Revision 1.2 Page iii ®®Table of Contents 1 Introduction ...

Pagina 19 - 6 Technical Specifications

ACM100 User’s Manual Page iv Revision 1.2 Figure 4 – Single-Phase (Dual Line) Connection Diagram ...

Pagina 20 - 7 Technical Support

Revision 1.2 Page 1 ®®1 Introduction Congratulations on your purchase of the Maretron Alternating Current (AC) Monitor (ACM100). Maretron

Pagina 21 - 8 Installation Template

ACM100 User’s Manual Page 2 Revision 1.2 o 230VAC single phase o 380VAC Y Three-phase (380Y) 1.3 Quick Install Installing the Maretron

Pagina 22

Revision 1.2 Page 3 ®®2.3 Mounting the ACM100 Attach the ACM100 securely to the vessel using the included stainless steel mounting screws

Pagina 23 - Interfacing

ACM100 User’s Manual Figure 2 – NMEA 2000® Connector Face Views 2.4.2 AC Sensor Connections The ACM100 sensor connections are made by connectin

Pagina 24

®® WARNING: If the supplied current transformer is placed around a wire carrying AC current, then extremely high voltages can develop on the out

Comentarios a estos manuales

Sin comentarios