Low Alert Clear Point – If the alert is active and the parameter value rises
above the value in this field, the alert will become inactive.
Clear Delay The parameter being monitored must rise above the Low Alert
Clear Point value for longer than the time in this field in order for the alert to
become inactive. The value is entered as minutes:seconds. If only one number is
entered, it will be interpreted as seconds.
In this example, the set point may be described in more than one unit, so
additional fields have been supplied so that the user can select the units of
depth. Changing the units of the set point will also change the units of the clear
point. The initial units displayed in these fields will correspond to those set in the
Units Dialog (see section 9.4.8.1).
10.3.6.4.3 Data Unavailable Alert
The Data Unavailable Alert can be used in conjunction with other alert types
when you need to know if a particular parameter is no longer being sent on the
network or is flagged as “not available” by the transmitting device. For instance,
you probably would want to use a Data Unavailable Alert for the Depth->Current
Depth parameter, since it would be advisable to know if the depth sounder were
to stop transmitting a depth reading or became unable to determine the depth
due to fouling or some other reason. On the other hand, if you were to set a
Data Unavailable Alert on Engine->Engine Water Temperature parameter, you
would then get an alert every time the ignition was switched off and the engine’s
ECU stopped transmitting data.
10.3.6.4.3.1 Trigger Configuration
Figure 90Trigger ConfigurationData Unavailable Alert
Accept Re-trigger PeriodWhen you accept an alert, it will change to the
“Accepted” state, and annunciators that are sounding for that alert will stop
sounding. If the condition which caused the alert remains true after the amount of
Revision 4.0.2 Page 260