13.6.2 Configuring Sources
The top portion of the screen shows the Sources being monitored. The Sources
are labeled “Source 0”, “Source 1”, “Source 2”, and “Source 3”. If the Source has
been set to an ACM100, and the ACM100 supplies a label, the label on the
control will be changed to that supplied by the ACM100.
The Digital Control shows both the current reported by the ACM100, and the
Load Shedding Current. A dash for the Load Shedding Current implies that the
source is not providing a current that can be monitored for load shedding. If the
user disables the source, it will show Disabled.
The LED on the Digital Control will show red when the reported current exceeds
the Load Shedding Current, yellow when the reported current is within 10% of the
Load Shedding Current and green when less than 90%.
The Source is configured my pressing the Edit Button, and may be enabled /
disabled from this dialog.
Figure 110 – Load Shed Source Dialog
The Digital Control shows the current reported by the ACM100.
The User can set the parameter to choose the correct ACM100 (Device Type
and ACM instance number) and the Load Shedding Current.