Maretron Alarm Module ALM100 Manual de usuario Pagina 343

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 380
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 342
11 BNWAS (Bridge Navigation Watch Alarm
System
From version 4.0.0 N2KView will support a Bridge Navigation Watch Alarm
system in compliance with IMO resolution MSC.128/75. Compliance to the
functional requirements of MSC.126/75 are as follows:
4.1.1 N2KView only supports the Manual ON and Manual OFF operational
modes.
4.1.2 Compliant. Audible alarm requirement is satisfied by Maretron
ALM100 annunciators.
4.1.3 Reset function is satisfied by touching the N2KView screen, clicking a
mouse, or pressing a key one the keyboard of N2KView.
4.1.4 Not supported.
11.1 Setting up BNWAS
From the Commands & Settings dialog press the BNWAS button to enter the
BNWAS Setup dialog. If the configuration is password protected, then you will
need to enter a password to enter this dialog.
At the bottom of the dialog is a diagram showing the stages of operation of the
BNWAS on a timeline. As you change the parameters, the values on the timeline
will change to reflect what the timings are.
Revision 4.0.2 Page 343