Figure 97 - Trigger Configuration – Anchor Watch Alert
Accept Re-trigger Period – When you accept an alert, it will change to the
“Accepted” state, and annunciators that are sounding for that alert will stop
sounding. If the condition which caused the alert remains true after the amount of
time in this field, the alert will return to the “Active” state, and annunciators will
begin sounding again for that alert.
If a value of 0:00 is entered, then the alert will never re-trigger.
Anchor Watch Alert Set – If the distance between the current GPS position and
the reference position rises above the value in this field, the alert will become
active.
Set Delay – The distance between the current GPS position and the reference
position must rise above the Outside Radius Alert Set value for longer than the
time in this field in order for an alert to become active.
Anchor Watch Alert Clear – If the alert is active and the distance between the
current GPS position and the reference position falls below the value in this field,
the alert will become inactive.
Clear Delay – The distance between the current GPS position and the reference
position must fall below the Anchor Watch Alert Clear value for longer than the
time in this field in order for an alert to become inactive.
Latitude – The latitude of the reference position. This may be typed in as
<degrees>:<minutes> followed by an N or S. If the N or S is missing, North is
assumed. Moving the cursor to another field will reformat the contents of this
field. For the Anchor Watch Alert, this field may be left blank if the alert is
disabled, enabling the Alert to be created in advance of anchoring.